Our website has been renewed!

GL-Connection– GL Series Integrated Waveform Viewer –

Software for high performance and easy operation
Allows connections of Graphtec’s midiLOGGER series

The GL-Connection software included with GL7000, GL2000 and GL980 can control devices.
It is an integrated application software for the GL series, the GL900, GL840, GL820, GL240 and GL220 can also be connected and controlled.

Supported Models

GL7000 Plus / GL2000 / GL980
GL840 / GL240 / GLT400 / GL900 /GL820/ GL220

GL-Connection

Various measurement screens

The measurement signal can be displayed in various types of screens adapted to applications.

Various measurement screens

Multi-window function, measured signal can be displayed in various forms

Multi-window function

The GL-Connection software supports up to 2000 channels and up to 20 units of the GL series. It splits up to 4 windows and each window can display different format for easy monitoring signal in large channels.

Multi-window function

When the unit of GL series is connected to the PC via Ethernet or USB, the GL-Connection software can manage a various information such as the data in capturing, data in the free running – displaying data without saving – and data in saved file.
The GL-Connection software can also display the data saved on the PC.

The GL-Connection software can also display the data saved on the PC

Tab function

The tab function allows you to manage the screen so that it can be intuitive and easy monitoring. Screen displayed in multi-window can split using the tab and selected items can be displayed. Items to be displayed can be set in detail, such as the GL body level, individual input module level, the specified channel, and other settings.

  • Copy of the entire tab
Copy of the entire tab
  • Copy of the channel
Copy of the channel
  • Move of the tab
Move of the tab
  • Cursor synchronization
Cursor synchronization
  • Release of remote lock of GL7000
Release of remote lock of GL7000

Integrated application software for the GL series

When the software is used with the GL7000, it can be controlled and displayed the data including the FFT measurement. When other GL series is used, the software has mainly the waveform viewing function and have also the function to control basic items. Data captured by other GL series is compatible with the GL-Connection and APS software.

Integrated application software for the GL series

Connection of multiple units and the integrating function of the saved data

GL-connection software will be able to manage multiple units in a mixed condition of the GL series. Data integration function allows you to understand the overall situation immediately by creating single file at the same time axis from multiple data file saved by each unit.

Scrollable
Connection methodModel Model
mixed
Control of Start/StopData integration
1.Multiple unit connectionMultiple unit connection
GL7000
GL2000
GL980
GL840
GL240
GLT400
YesIt make operation for each unit.It makes manually
after completing the data capture.
2.Link connection
(simultaneous)Link connection (simultaneous)
GL7000
GL2000
GL980
GL840
GL240
GLT400
YesAll units make the action
in a single operation.
* The timing of the action is maybe synchronized.
It makes automatically
after completing the data capture.
It can also make manually.
3.Link connection
(synchronous)
* Sync cable is used to connect each unit.Link connection (synchronous)
GL7000 NoAll units make the action
with full synchronization
in a single operation.
It makes automatically
after completing the data capture.
It can also make manually.
4.Mixed connection,
mixing of No.1 to No.3Mixed connection, mixing of No.1 to No.3
GL7000
GL2000
GL980
GL840
GL240
GLT400
Way of operation or action vary
by type of connection that is the No.1 to No.3.
* Full synchronization can be made when the sync cable is used in the GL7000.
  • Work flow of data integration
Work flow of data integration
  • The integrated file cannot be created when it exceeds 100 units or 100 channels (analog channel + logic channel).
  • Data will be integrated with using fastest sampling speed when the sampling speed in each file is different.
  • The data format in integrated data file is the GL7000 format even if GL series is included to capture the data.

Main function of software

Scrollable
ItemDescription
GL-Connection
(version 2.0 or later)
ConnectionSupported modelGL7000, GL2000, GL980
GL900-4/-8 (Firm. v. 3.01 or later)
GL840 (Firm. v. 1.21 or later)
GL820 (Firm. v. 1.08 or later)
GL240 (Firm. v. 1.21 or later)
GL220 (Firm. v. 1.06 or later)
Max. number of unit20
Max. number of channel2000
Mixing the USB & LANPossible
DisplaySplitting of screenUp to 4 screens
Group functionUp to 20 groups
GL980_2000-APSConnectionSupported modelGL2000/GL980
Max. number of unit1
Max. number of channel4 or 8
Mixing the USB & LANN/A
DisplaySplitting of screenNo, single screen
Group functionN/A
GL100_GL240_GL840-APSConnectionSupported modelGL840/GL820/GL240/GL220/GL100
Max. number of unit10
Max. number of channel1000
Mixing the USB & LANPossible
DisplaySplitting of screenNo, single screen
Group functionUp to 4 groups
GL220_820-APSConnectionSupported modelGL820/GL800/GL220/GL200A
Max. number of unit10
Max. number of channel500
Mixing the USB & LANN/A
DisplaySplitting of screenNo, single screen
Group functionUp to 4 groups
GL900-APSConnectionSupported modelGL900-4/GL900-8
Max. number of unit1
Max. number of channel4 or 8
Mixing the USB & LANN/A
DisplaySplitting of screenNo, single screen
Group functionN/A

Supported model and condition of connection

Scrollable
Supported modelConnected by USBConnected by LANWireless LAN
Notice
GL7000YesYesN/A(1) GL series up to 20 units
(2) Up to 2000 channels
GL2000 / GL980YesYesN/A
GL840YesYesYes
GL240YesN/AYes
GLT400YesYesYes
GL900YesYesN/A
GL820YesYesN/A
GL220YesN/AN/A
  • using B-568 option.

Sampling Limits

High speed sampling is limited by the number of recording channels, connected modules, and the recording destination, etc. Even within the following limits, transmission may be incomplete due to transmission delays with multiple module connections, especially with LAN connections. If this occurs, please reduce the sampling rate. For more details on the GL device limits, please refer to the main module user’s manual on CD-ROM.

GL7000

Scrollable
NameExplanation
Module-based limits
(GL device limits)
Voltage module1 ms
Voltage / Temperatuer module10 ms
High Speed Voltage / High Voltage module1 µs
DC Strain / Charge module10 µs
Logic / Pulse moduleLogic: 1 µs / pulse: 100 µs
Recording destination-based limits
(GL device limits)
Internal RAM1 µs
Internal flash1 ms
SD card1 ms
SSD module1 to 2 modules:1 µs; however, the pulse runs only until 8ch
3 to 4 modules: 2 µs; however, the pulse is only until 16ch
Over 5 modules: 5 µs
Main module recording format-based limits
(GL device limits)
GBD (binary)1 µs
CSV (Text)10 ms
Ring recording-based limit.
(GL device limits)
Ring recording-based limit. (GL device main module limits)
When ring recording is on:100ms (Only when Internal Flash, SD card, SSD module)
Calculation function-based limits
(GL device limits)
100 ms
* The GL device’s calculation function cannot be used with this application.
 There is no calculation function in this application.
Transmission-based limits
(Application limits)
There are estimated sampling settings for PC recording depending on the volume of data communication.
* When connecting through an existing network such as a LAN connection, communication may not be possible within the following limits. In such a case, please use a USB connection, or set a lower sampling rate.

Estimated sampling rates

USB connectionGBD (binary) format1 ms / 5 module (*)
CSV (text) format1 ms / 5 module (*)
LAN connectionGBD (binary) format1 ms / 5 module (*)
CSV (text) format1 ms / 5 module (*)

GL840、GL240、GLT400、GL820、GL220

Scrollable
NameExplanation
Limitations by amplifier (Limitations of the GL module side)Number of CH availableFastest sampling
110 ms
220 ms
3 to 550 ms
6 to 10100 ms
11 to 20200 ms
21 to 50500 ms
51 to 1001 s
101 to 2002 s
* The number of channels of the GS/WL sensors is not included
Main module recording format-based limits
(GL device limits)
GBD (binary)10 ms
CSV (Text)100 ms (* 10ms – for GL240 and GL840)

GL2000GL980

Scrollable
NameExplanation
Recording destination-based limits
(GL device limits)
Internal RAM1 µs
Internal flash1 ms
USB memory1 ms
Main module recording format-based limits
(GL device limits)
GBD (binary)1 ms
CSV (Text)1 ms

GL900

Scrollable
NameExplanation
Recording destination-based limits
(GL device limits)
Internal RAM10 µs
Internal flash1 ms
USB memory1 ms
Main module recording format-based limits
(GL device limits)
GBD (binary)1 ms
CSV (Text)10 ms

Functions

Scrollable

Item

Description

Module Settings ListSettings of multiple modules can be displayed simultaneously, and setting conditions can now be saved as CSV data.
Remote Lock On/Off FeatureSetting operation is available on GL7000 under control of GL-Connection.
Statistics / DisplayDisplay statistical calculation result.
Capturing data: Maximum, Minimum, Peak or Average
Replaying data: Maximum, Minimum, Peak, Average or RMS in between cursors
Check-sum functionIt is a function to check data file consistency. The check-sum code is recorded into the file when data file is created by the GL unit. When the content of the file is changed by someone, the check-sum generated from the file does not match with the recorded check-sum, which indicates that the file has been tampered with.
* This software and the firmware on the GL unit need to be a version that supporting the check-sum function.
File operationConverts binary data to the CSV data (specific period, all data in one file, multiple files), Creates a new file with compression or by consolidating multiple files.
Search functionSearch any point on the data.
Level: Specific level in any channels
Alarm: Occurred alarm in any channel
Time: Beginning, center, end of the data, Trigger point, Specific time (absolute, relative), Specific number
Warning functionSend e-mail to the specified address when the alarms occur